Commissioning & Testing in India
End-to-end acceptance testing, documented results and a handover pack that stands up to audit. delivered in India by engineers who work to the standards, safety regime and documentation expectations of this market. Mobilisation from Mumbai in 24 hours. India is adding capacity faster than almost any market, across Mumbai, Delhi NCR, Bengaluru, Chennai and Hyderabad. The practical differentiators are BIS-compliant materials, sector regulators with their own rules, and the sheer scale of campus builds.
- Mobilisation
- 24 hours
- Hubs
- Mumbai · Bengaluru · Chennai · Hyderabad · Delhi NCR
- Region
- Asia-Pacific
- Mains supply
- 230/415 V, 50 Hz
- On-site languages
- English, Hindi
- Local entity
- Field hubs and partners
The India market
India is adding capacity faster than almost any market, across Mumbai, Delhi NCR, Bengaluru, Chennai and Hyderabad. The practical differentiators are BIS-compliant materials, sector regulators with their own rules, and the sheer scale of campus builds.
We mobilise from Mumbai and Bengaluru and Chennai and Hyderabad and Delhi NCR with a target of 24 hours to site. Mumbai, Bengaluru, Chennai, Hyderabad and Delhi NCR hubs give 24-hour mobilisation in those metros. Tier-2 cities are served by scheduled mobilisation.
Our India footprint
- Mumbai
- Bengaluru
- Chennai
- Hyderabad
- Delhi NCR
Mumbai, Bengaluru, Chennai, Hyderabad and Delhi NCR. Local engineering teams for build-outs and field support at scale.
All 28 covered countriesLocal delivery
How we deliver commissioning & testing here
Commissioning in India produces the evidence pack that closes the project: IEC 61935-1 or TIA-1152 certification to match the specification, fibre to IEC 61280-4-2 with OTDR traces. English reporting. Every test is traceable to a link, an outlet or a rack, because an aggregate pass rate is not something an auditor can use.
- Test plan agreed in advance, naming the standard, the limits and the pass criteria
- Copper and fibre certification on 100% of links, with failures re-terminated and re-tested
- Native test files delivered alongside the human-readable report, so results can be re-verified independently
- Power-on and functional checks recorded per rack, including failover where it is in scope
- Punch list closed out and re-tested before the handover is signed
Standards and compliance in India
Work is signed off against the standards that actually apply here, not the ones our engineers are most familiar with. In India that means IS/ISO/IEC 11801 and IS 16605 as the primary reference, with iec 61935-1 or tia-1152 certification to match the specification as the test regime.
Site safety runs under Factory Act and site-specific permit-to-work regimes. We supply certificates before mobilisation rather than on request.
Standards applied on site
- IS/ISO/IEC 11801 and IS 16605 for cabling, alongside EN or TIA specifications from the client
- TIA-942 tier ratings widely referenced by developers
- IS 732 and NBC 2016 Part 8 for electrical installation
- DPDP Act 2023 and rules for personal data processing
- RBI outsourcing and IT-governance directions for banks and NBFCs
- IRDAI and SEBI guidance for insurance and capital-markets tenants
- MeitY empanelled-auditor requirements for CERT-In directions
Site access and safety
Campus access requires photo ID and advance registration, sometimes with police verification for long-term personnel. Allow 48 hours for first-time access.
- Factory Act and site-specific permit-to-work regimes
- Electrical work by licensed personnel under the state electricity rules
Related work
Commissioning & Testing delivery cases
DACH · 2024
420-rack hyperscale fit-out, Frankfurt
Three data halls brought to production in a single quarter, with configuration drift controlled by wave-based validation rather than end-of-project inspection.
UK & Ireland · 2023
Two server rooms migrated in one weekend, London
A consolidated move of two legacy server rooms into a colocation suite over a single 54-hour window, with rollback positions agreed before anything was de-racked.
Benelux · 2024
14,000-link fibre and copper refresh, Amsterdam
A live-facility cabling refresh replacing end-of-life OM3 with OM4 and OS2, delivered in occupied halls without a single unplanned customer outage.
Local questions
Working in India
Do you use BIS-compliant materials?
Yes. Cables, cords and accessories are BIS-marked where the standard applies, and we supply the conformity documentation with the handover pack.
Can you support RBI or IRDAI-regulated tenants?
We provide the change records, test evidence and asset documentation those regulators expect from a service provider. We do not provide regulatory advice.
How do you handle large campus builds?
With a fixed team and a phased plan, so knowledge stays on site and quality does not drift across phases. We size crews per phase and report daily.